System Performance Specifications
|
|
Average Permeate Flow Rate: 50 gallons/day
|
|
Average TDS Rejection: 90% NaCI based on 50psi under 25°C
|
|
Minimum and Maximum Performance Specifications
|
| Specification |
Average |
| Permeate Flow Rate |
50 Gallons/day |
| TDS Rejection (NaCI) |
90% |
| Concentrate Flow |
200 Gallons/day |
|
|
General Dimensions(including package)
|
|
Length: 35 cm
|
|
Width: 42 cm
|
| Height: 58 cm |
| Minimum and Maximum Operating Conditions |
| Condition |
Minimum |
Maximum |
| Voltage |
AC 220V~DC 24V |
| Flush control |
Ball valve(by manual) |
| Inlet Pressure |
0.5kg |
3kg |
| Inlet Temperature |
5° C |
45° C |
| Inlet TDS |
0 mg/L |
500 mg/L |
| Inlet Hardness |
0 grains/gallon |
10 grains/gallon |
| Inlet Chlorine |
0 ppm |
0.2 ppm |
|
| Tubing/Fitting Dimensions |
| Inlet Tubing: 1/2" natural
tubing |

|
| Concentrate(Drain) Tubing:
1/2"tubing |
| Permeate Tubing: 1/2"
tubing |
|
Joints: 4044 |
7pics |
|
4042 |
3pics |
|
7544 |
2pics |
| 6044 |
2pics |
| 4046 |
2pics |
|
702 |
1pics |
| 1044 |
1pics |
|
| Filter/Membrane Performance Specifications |
| Filter Type |
Flow
Rate |
Average Life |
| 5u PP-Filter |
3.75 GPM |
3 months |
| T33 Carbon Filter |
3.75 GPM |
6 months |
| CTO Carbon Filter |
0.375 GPM |
6 months |
| RO Membrane |
0.375 GPM |
1~2 years |
| Small T33 Carbon Pack-placed |
0.750 GPM |
6 months |
|
| Model Specifications |
| Type |
Flow Specifications |
Function |
| CB-50B |
50 GPD |
Flush by manual |
| CB-50C |
50 GPD |
Flush by Solenoid Valve |
| CB-50D |
50 GPD |
Flush by Computer Control Panel |
| CB-50DT |
50 GPD |
This Computer Control Panel can display TDS |
|
| The all type has the same Dimensions. |