300~400 gallon Reverse Osmosis System Specifications

CB-100 System Performance Specifications
Average Permeate Flow Rate: 300 gallons/day
Average TDS Rejection: 90% NaCI based on 50psi under 25°C
Minimum and Maximum Performance Specifications
Specification Average
Permeate Flow Rate 300 Gallons/day
TDS Rejection (NaCI) 90%
Concentrate Flow 600 Gallons/day
General Dimensions(including package)
Length: 68 cm
Width: 48 cm
Height: 108 cm
Minimum and Maximum Operating Conditions
Condition Minimum Maximum
Voltage AC 220V~DC 24V
Flush control Ball valve(by manual)
Inlet Pressure 0.5kg 3kg
Inlet Temperature 5° C 45° C
Inlet TDS 0 mg/L 500 mg/L
Inlet Hardness 0 grains/gallon 10 grains/gallon
Inlet Chlorine 0 ppm 0.2 ppm
Tubing/Fitting Dimensions
Inlet Tubing: 3/8" natural tubing

Concentrate(Drain) Tubing:3/8" tubing
Permeate Tubing: 3/8" tubing
Joints:
4042 9pics
7544  3pics
4044 2pics
2544 2pics
706 2pics
1564 1pics
1566  1pics
154  3pics
4066  9pics
4046  2pics
702  6pics
Filter/Membrane Performance Specifications
Filter Type Average Life
5u PP-Filter 3 months
T33 Carbon Filter 6 months
CTO Carbon Filter 6 months
RO Membrane 1~2 years
Small T33 Carbon Pack-placed 6 months
Model Specifications
Type Flow Specifications Function
CB-300I 300 GPD 两位开关控制
CB-300II 300 GPD 面板上有流量计压力表
CB-400I 400 GPD 两位开关控制
CB-400II 400 GPD 面板上有流量计压力表
The all type has the same Dimensions.